VLF Testing Of MV Cable | VLF Test Procedure | VLF Cable Testing | Inspection Of Electrical Networks
♥LIKE | ♥COMMENT | ♥SHARE | ♥SUBSCRIBE
Hello! Friends I am Muhammad Asif Ek Aur new video♥ VLF Testing Of MV Cable | VLF Test Procedure | VLF Cable Testing | Inspection Of Electrical Networks | فحص شبكات كهرباء | فحص شبكة كهرباء | MM Asif | ke sath Huzoor Hoon.
Mastering VLF Testing for MV Cables | A Comprehensive Tutorial
Dive into the world of Very Low Frequency (VLF) testing with our expert-led tutorial. Learn the ins and outs of VLF testing procedures and how they are crucial for the inspection of electrical networks.
🔌 What You’ll Discover:
The importance of VLF testing for medium voltage (MV) cables and its role in maintaining network integrity.
A step-by-step guide to VLF cable testing, ...
Просмотров: 1 331

Видео

Step-by-Step: 300mm Cable Termination in Electrical Panels | LV Cable Termination | MM Asif
Просмотров 4,4 тыс.2 месяца назад
♥LIKE | ♥COMMENT | ♥SHARE | ♥SUBSCRIBE Hello! Friends I am Muhammad Asif Ek Aur new video♥ Step-by-Step: 300mm Cable Termination in Electrical Panels | LV Cable Termination | MM Asif | ke sath Huzoor Hoon. Welcome to the definitive guide on 300mm Cable Termination in Electrical Panels . Join MM Asif as he takes you through the intricate process of low voltage cable termination with precision an...
Understanding Transformer Structures: A Step-by-Step Guide in Hindi | Double Pole & DTR Explained
Просмотров 9952 месяца назад
♥LIKE | ♥COMMENT | ♥SHARE | ♥SUBSCRIBE Hello! Friends I am Muhammad Asif Ek Aur new video♥ Understanding Transformer Structures: A Step-by-Step Guide in Hindi | Double Pole & DTR Explained | MM Asif | ke sath Huzoor Hoon. Dive into the intricate world of transformers with our comprehensive guide, “Understanding Transformer Structures: A Step-by-Step Guide in Hindi/Urdu/Tamil.” This video is per...
Crimping Made Easy: Best Hydraulic Tools for Electrical Work | Crimping Tool For Cable | MM Asif
Просмотров 5602 месяца назад
♥LIKE | ♥COMMENT | ♥SHARE | ♥SUBSCRIBE Hello! Friends I am Muhammad Asif Ek Aur new video♥ Crimping Made Easy: Best Hydraulic Tools for Electrical Work | Crimping Tool For Cable | MM Asif | ke sath Huzoor Hoon. 🔌🛠️ Crimping Made Easy: Best Hydraulic Tools for Electrical Work 🛠️🔌 Are you tired of struggling with manual crimping tools? Say hello to hydraulic crimpers-the secret weapon for efficie...
Method of Installation of Electric Transformer | Electric Transformer Installation | MM Asif
Просмотров 7243 месяца назад
Method of Installation of Electric Transformer | Electric Transformer Installation | MM Asif
How To Use Rammer Compactor | Use A Jumping Jack Compactor | Rammer Compactor and How Does It Work
Просмотров 4293 месяца назад
How To Use Rammer Compactor | Use A Jumping Jack Compactor | Rammer Compactor and How Does It Work
How To Low Voltage Cable Termination In Panel | Termination Low Voltage Cable | MM Asif
Просмотров 1,5 тыс.3 месяца назад
How To Low Voltage Cable Termination In Panel | Termination Low Voltage Cable | MM Asif
Medium Voltage Cable Termination | MV Cable Termination | MV Cable Termination Procedure | MM Asif
Просмотров 3,1 тыс.3 месяца назад
Medium Voltage Cable Termination | MV Cable Termination | MV Cable Termination Procedure | MM Asif
How to Install Cables Under the Road Using Horizontal Drilling | Drilling For Cable Laying
Просмотров 1,5 тыс.4 месяца назад
How to Install Cables Under the Road Using Horizontal Drilling | Drilling For Cable Laying
How to Lay Electrical Cable Underground | Underground Cable Installation | Cable Laying | MM Asif
Просмотров 4 тыс.5 месяцев назад
How to Lay Electrical Cable Underground | Underground Cable Installation | Cable Laying | MM Asif
Plastic Pipe Welding Machine Demo: How It Works? MM Asif
Просмотров 8505 месяцев назад
Plastic Pipe Welding Machine Demo: How It Works? MM Asif
How To Use A Megger To Test Wire Insulation | Megger Testing Electrical Wiring | MM Asif
Просмотров 1,7 тыс.5 месяцев назад
How To Use A Megger To Test Wire Insulation | Megger Testing Electrical Wiring | MM Asif
How to Terminate Cables into an Electrical Panel | Cable Entry Methods | Cable Termination In Panel
Просмотров 3 тыс.6 месяцев назад
How to Terminate Cables into an Electrical Panel | Cable Entry Methods | Cable Termination In Panel
How to Terminate a 300mm Aluminum Underground Cable in a Distribution Panel - Step by Step Guide
Просмотров 7 тыс.10 месяцев назад
How to Terminate a 300mm Aluminum Underground Cable in a Distribution Panel - Step by Step Guide
How To Install Suspension Insulators: A Step-by-Step Guide | overhead line Suspension Insulators |
Просмотров 6 тыс.10 месяцев назад
How To Install Suspension Insulators: A Step-by-Step Guide | overhead line Suspension Insulators |
How To Connect 3 Phase Cable | Electric Meter Cable Connection | Three Phase Cable Connection
Просмотров 2,9 тыс.11 месяцев назад
How To Connect 3 Phase Cable | Electric Meter Cable Connection | Three Phase Cable Connection
How To Joint Underground Cable | Underground Cable Straight Joint | 11kv Xlpe Cable Joint | MM Asif
Просмотров 530 тыс.Год назад
How To Joint Underground Cable | Underground Cable Straight Joint | 11kv Xlpe Cable Joint | MM Asif
How to Lay Underground Cable Like a Boss | MM Asif Electrical Work | Underground Cable Installation
Просмотров 6 тыс.Год назад
How to Lay Underground Cable Like a Boss | MM Asif Electrical Work | Underground Cable Installation
Mastering Water-Filled Barriers: Installation Tips and Road Safety Insights” 🚧🌊
Просмотров 1,3 тыс.Год назад
Mastering Water-Filled Barriers: Installation Tips and Road Safety Insights” 🚧🌊
Trenching For Electrical Line | Digging Trench For Electrical Conduit | MM Asif
Просмотров 2,6 тыс.Год назад
Trenching For Electrical Line | Digging Trench For Electrical Conduit | MM Asif
Underground Cable | Cable Laying Work | Underground Cable Laying | 11kv cable installation | MM Asif
Просмотров 23 тыс.Год назад
Underground Cable | Cable Laying Work | Underground Cable Laying | 11kv cable installation | MM Asif
Feeder Pillar Installation Details | Feeder Pillar Panel | Feeder Pillar | Mini Pillar Electrical |
Просмотров 8 тыс.Год назад
Feeder Pillar Installation Details | Feeder Pillar Panel | Feeder Pillar | Mini Pillar Electrical |
Step Down Transformer | Transformer Step Down Voltage | Types of Transformer | Electric Transformer
Просмотров 3,3 тыс.Год назад
Step Down Transformer | Transformer Step Down Voltage | Types of Transformer | Electric Transformer
Cable Termination In Panel | Terminate Medium Voltage Cable | Underground Cable Termination
Просмотров 3,5 млнГод назад
Cable Termination In Panel | Terminate Medium Voltage Cable | Underground Cable Termination
Electrical Panel Wiring | What are Electric low voltage panels? | Work in low voltage panel |MM Asif
Просмотров 4,3 тыс.Год назад
Electrical Panel Wiring | What are Electric low voltage panels? | Work in low voltage panel |MM Asif
How to Use a Cutting Torch | Oxy Acetylene Torch Cutting | Gas Torch Cutting | MM Asif
Просмотров 1,2 тыс.Год назад
How to Use a Cutting Torch | Oxy Acetylene Torch Cutting | Gas Torch Cutting | MM Asif
Electrical Materials Names and Pictures | Electrical Accessories | Electrical Materials List
Просмотров 4 тыс.Год назад
Electrical Materials Names and Pictures | Electrical Accessories | Electrical Materials List
How To Joint Electrical Cable | Electrical Cable Joint Connector | Cable Jointing Training in Hindi
Просмотров 6 тыс.Год назад
How To Joint Electrical Cable | Electrical Cable Joint Connector | Cable Jointing Training in Hindi
Cable Lugs Types And Name | Types Of Cable Lugs | Cable Lugs Size | Electrical Cable Thimble
Просмотров 7 тыс.2 года назад
Cable Lugs Types And Name | Types Of Cable Lugs | Cable Lugs Size | Electrical Cable Thimble
3 Phase Energy Meter Connection | How To Install 3 Phase Energy Meter | Install 3 Phase Meter Box
Просмотров 126 тыс.2 года назад
3 Phase Energy Meter Connection | How To Install 3 Phase Energy Meter | Install 3 Phase Meter Box

Комментарии

  • @walterrumohr7090
    @walterrumohr7090 16 часов назад

    Wow wow.

  • @MAbid-zt7nm
    @MAbid-zt7nm День назад

    Bhai 10mm armound cable 4 core To jo amp bata rahay ho ye per phase ke hain amps matlab 3 phase main her phase alag alag itna load daal saktay hain 10mm 4 core armoured cable pe

  • @eplumer
    @eplumer 4 дня назад

    now that’s a crimper!

  • @LIVE-dm6rc
    @LIVE-dm6rc 4 дня назад

    All the beauty got ruined at final thanks to those damn groundings. Great job anyway 😉

  • @PeteDavidson-yl3ps
    @PeteDavidson-yl3ps 5 дней назад

    Very scary when qualified Installers need to READ instructions from the Manufacturer....like is this your FIRST TIME Boys ?

  • @_mklein
    @_mklein 7 дней назад

    However says they done a great job don’t have a clue about how bad this is!

  • @KonanNiankoun
    @KonanNiankoun 8 дней назад

    C'est très bien

  • @owaisbinkhaliddar6000
    @owaisbinkhaliddar6000 8 дней назад

    nothing about Smart Meters.......

  • @alexivanov2891
    @alexivanov2891 8 дней назад

    9:04 outer wires are half-cut damaged. Is this normal ?

  • @ScottDLR
    @ScottDLR 9 дней назад

    I'm surprised they don't have a purpose-built wire stripper. They left some deep nicks in those wires.

  • @user-uh5wu1tz5x
    @user-uh5wu1tz5x 9 дней назад

    Сечение жил кабеля против сечения шпилек на проходных изоляторах вызывает дикое сомнение...

  • @arafathossain4343
    @arafathossain4343 10 дней назад

    Very good job 😊

  • @jermainewashington7447
    @jermainewashington7447 10 дней назад

    Sloppy sloppy sloppy. What country manufactured the transformer and the cables?

  • @prashantpatel5738
    @prashantpatel5738 15 дней назад

    Wrong method

  • @abidali.6873
    @abidali.6873 16 дней назад

    Good 👍

    • @mmasif7364
      @mmasif7364 10 дней назад

      Thanks for the visit

  • @ahmadmohmed4448
    @ahmadmohmed4448 16 дней назад

    what's the name of the tool @ 11:56?

    • @mmasif7364
      @mmasif7364 10 дней назад

      hydraulic crimping tool

  • @franciscorafael7975
    @franciscorafael7975 17 дней назад

    PURO INGENIERO DA SU PUNTO DE VISTA, NO TIENEN M@........ QUE FEA ES LA ENVIDIA. Porque no van y lo hacen ustedes que si saben. pero estan viendo el video, hasta la marca de las moscas y hormigas. QUE FEO.. BUEM TRABAJO.

  • @franciscorafael7975
    @franciscorafael7975 17 дней назад

    Que mala onda de TODOS LOS COMENTARIOS, de repente todos son INGENIEROS, yo creo que son puras mulas, BONITO TRABAJO. ✔✔

  • @alekiri
    @alekiri 19 дней назад

    Они кабель пилили полотном по дереву ?

    • @Inkarnar
      @Inkarnar 15 дней назад

      Весь монтаж вообще полное извращение!

  • @ProductionJourneyDG-kc8jb
    @ProductionJourneyDG-kc8jb 22 дня назад

    🤔🤔

  • @siriosstar4789
    @siriosstar4789 22 дня назад

    pretty sure i saw those cables at the Munich High End show recently .

  • @user-yr9id2yp5w
    @user-yr9id2yp5w 23 дня назад

    I would have liked to see how you stripped the insulation of the larger cable to expose the conductors. Great work :)

  • @Lycoris-tc6nv
    @Lycoris-tc6nv 27 дней назад

    Я надеялась, что они с размерами напортачат и кабель запорят!

  • @ronaldviens7862
    @ronaldviens7862 29 дней назад

    If you start the torch on the shrink tubing at the bottom, you take advantage that heat rises and you won't scorch the shrink tubing. Nothing says "Quality work" better than scorched shrink wrap or nicks in your conductor. And that's a hellacious dielectric. No phase tape. Makes me wonder if this is even in the US. Yeah, there's sharpie letters, but sharpie disappears just cause of the air. And they're pretty strict about phasing your conductors here in the USA.

  • @hariomsingh3002
    @hariomsingh3002 29 дней назад

    I am from India very nice vdo bro really nice 👍

  • @solvated_photon
    @solvated_photon Месяц назад

    4:05 it’s better to start tape wrapping at the bottom and move up towards the top. This way each wrap covers the top edge of the last the way that shingles do and help prevent water getting under the tape.

  • @michaelsharp9925
    @michaelsharp9925 Месяц назад

    This sh*t wouldn’t fly in canada

  • @Crazy--Clown
    @Crazy--Clown Месяц назад

    You should go back to termination school. lol what a bozo

  • @dakmycat3688
    @dakmycat3688 Месяц назад

    Then some tweaker will come along and take it apart in five minutes 😳😂🤣

  • @sandeepsharma5135
    @sandeepsharma5135 Месяц назад

    कितने mm ki h ji

  • @SteelersNSalsa_deMex1co
    @SteelersNSalsa_deMex1co Месяц назад

    I service this kind of stuff, my cup of tea.

  • @SPUDHOME
    @SPUDHOME Месяц назад

    Reading the instructions while you connect high voltage?

  • @jesuscaicedo6561
    @jesuscaicedo6561 Месяц назад

    Lo único malo q es en aluminio

  • @Ogcbesty
    @Ogcbesty Месяц назад

    This is confusing and seemingly good

  • @user-kf4ob1yh3g
    @user-kf4ob1yh3g Месяц назад

    Maining GTX 10.000

  • @user-kf4ob1yh3g
    @user-kf4ob1yh3g Месяц назад

    Вот какие нужны кабеля под потолком длинной 600 и на 60м квартиру и сто рубильников

    • @Inkarnar
      @Inkarnar 15 дней назад

      Обыватель не потянет такой профессиональный монтаж для однокомнатной...

  • @shehzadjutt500
    @shehzadjutt500 Месяц назад

    جناب سٹی کا کیا فنکشن ہے اور ایک گھنٹے میں کتنے یونٹ گرتے ہیں اس سیٹنگ سے

  • @FOH3663
    @FOH3663 Месяц назад

    I can smell that "grape" semiconductor from here.

  • @atiqrehman5090
    @atiqrehman5090 Месяц назад

    Sir g plz

  • @atiqrehman5090
    @atiqrehman5090 Месяц назад

    Sir g AP ki help chayia plz apna Whatsapp num send karo g

  • @atiqrehman5090
    @atiqrehman5090 Месяц назад

    Sir g plz 🙏 apna Whatsapp num send karo g

  • @tsclly2377
    @tsclly2377 Месяц назад

    looking at the cable, I think that some-one misplaced a decimal point, as one would not want to use any voltage below 400V/3phase for any substantial length .. this looks like 200V and looking for a 1.5% drop. maybe this is cheaper than a transformer in the short run. the cable looks to be 2.5cm dia. PLUS the definition of " Medium Voltage Cables" is 2.4kV and above.. so is it MW that we are really looking at?

  • @user-hf5hl6qb5u
    @user-hf5hl6qb5u Месяц назад

    Scientists have proven that blue duct tape is more reliable

  • @user-ov1oj4mf1x
    @user-ov1oj4mf1x Месяц назад

    Sar.me.thekedar.ho.mal.kharidna.me.m.p.se.hame.apna.nmbar.de

  • @torelipse4558
    @torelipse4558 Месяц назад

    Кабель 1200 мм^2 на болтик М19. Он бедный гореть не долго будет!

    • @Inkarnar
      @Inkarnar 15 дней назад

      На превью, вроде, 13,8 кВ - болтик выдержит, а вот кабель тонковат. 😉

  • @NiKolyan96
    @NiKolyan96 Месяц назад

    Михалыч! мы внешнюю термоусадку забыли надеть. снимай обратно! xD

  • @MD-nk8qf
    @MD-nk8qf Месяц назад

    You never wanna use a constructive material to secure MV cables inside equipment. Proper application would've been some sort of fiberglass bracing. Was not fond of the stress cones on those MV terminations. Tying and bonding to a grounded rod or job ground-loop may have been a better idea. I've had to do so even on smaller, pad-mounted XFMRs.

  • @ergyxhika2994
    @ergyxhika2994 Месяц назад

    123467🇬🇫🇫🇮?

  • @khayyam741
    @khayyam741 Месяц назад

    They should avoid getting the adhesive on the mating surfaced that carry current while applying it for insulation.